Box compression calculator

Estimate how much weight a corrugated box can carry before it crushes. The calculator works out the box compression strength (BCT) from the board grade and box size with the McKee formula, then takes off strength for time, humidity and how the pallet is built.

Box, outside size
Storage and stacking
Pallet load (optional)

229 lbf safe load on one box

Lab BCT
562 lbf
Strength kept
41%
Boxes on top
11
Column height
120 in

The bottom box carries 80 lb and can take 229 lbf: 2.9 times what it carries.

BCT = 5.87 × ECT × √(perimeter × caliper) = 5.87 × 32 × √(56 × 0.16) in inches and pounds.

An estimate for regular slotted boxes with the flutes vertical. Handholes, print, wet product or a filled box that supports the load change the real strength. Test the box before you rely on it.

Where the strength goes

ConditionYour choiceKeeps
Time under load30 days under load60%
Humidity70%80%
Stacking patternColumn stacked, aligned100%
OverhangNo overhang100%
Pallet deckGaps between deck boards85%
HandlingNormal handling100%
All together562 lbf lab strength41%

The McKee formula

The simplified McKee formula estimates the top-to-bottom compression strength of a regular slotted box: BCT = 5.87 × ECT × √(P × t). ECT is the edge crush strength of the board in pounds per inch, P is the box perimeter (twice length plus width) in inches and t is the board thickness in inches. A 16 by 12 inch box in 32 ECT C flute board, about 0.16 inch thick, comes to about 562 pounds.

Why boxes fail below their rating

A lab test crushes a dry box in about a minute. In a warehouse the load sits for weeks in damper air. Thirty days under load keeps about 60% of the strength, 80% humidity keeps about 68%, and interlocking the layers can halve it. Multiplied together, a box can end up with a quarter of its lab figure, which is why packaging engineers design to a safety factor.

Build stronger pallet loads

Column stack the boxes so the corners line up, keep cartons inside the deck, and use a pallet with tight deck boards. Stacking a second pallet doubles the load on the bottom layer. Plan the layers in the pallet calculator, then check the bottom box here.

Questions

How do I calculate box compression strength?

Use the simplified McKee formula: BCT = 5.87 × ECT × √(perimeter × caliper), with ECT in pounds per inch and the box perimeter and board caliper in inches. A 16 by 12 inch box in 32 ECT C flute board comes to about 562 pounds.

How much weight can a 32 ECT box hold?

It depends on the box size. A 16 by 12 inch 32 ECT C flute box tests at about 560 pounds, but after 30 days under load at 70% humidity it keeps about half of that, so plan on roughly 270 pounds on the bottom box.

Why do boxes fail below their rated strength?

Lab tests are short and dry. Time under load, humidity, interlocked stacking, overhang and gaps in the pallet deck each take strength away, and together they can leave a quarter of the lab figure.

Does interlocking the pallet pattern weaken boxes?

Yes. Interlocked layers put box corners over the middle of the panels below, which can cut compression strength by 40 to 60%. Column stacking keeps the corners aligned.

What ECT do I need?

Work out the load on the bottom box, divide by the strength you expect to keep after storage and stacking losses, and solve the McKee formula for ECT. The calculator does this when the bottom box is overloaded.